133 Sunstone way

Twenty20 & Co Inc

Report Cover Image
the-dwelling.png
133 Sunstone way Jun 27, 2025 at 12:36pm MDT

Jun 23, 2025

"Every little thing matters. The devil is in the details."

the insurance

stuff you'll need for your insurance policy

Inspectagram Barcode
the

insurance

Overview
Build Year 2025 also refer to permit / DP / BP
Outdoor Temperature Approx +16°C / 60° F / Also see weather network
Direction Home Faces Undetermined / Also see listing details
# Stories / Vacancy Basement +2 Floors / Vacant / Trades on site
Roof & Attic
Limitations → Visibility / Height / Safety
Roof Material Asphalt Architecual Shingle / Damage noted
Age / Condition Brand New / Good Condition
Roof flashing(s) Limited visibility / Missing kick out over garage
Roof Vent / Stack Present / Present (as seen with drone)
Gutter / Spout Matl. Metal - keep clear of debris & obstructions
Soffit / Fascia Matl Soffit: Metal / Facia: Composite (or like)
Sheathing /Condition OSB (oriented strand board) / minor damage
Attic Approx R-Value R-40+ 10” to 16” (Unevenly distributed)
Type of Insulation Cellulose or like / Loose Fill
Attic Util./ Baffles Inspected For Connections/ Present (Ltd. Vis.)
Exterior & Garage
Limitations → Visibility / Access / Height
Flat Work / Grading Seasonal incomplete / no driveway
Window / Condition See photos / brand new condition
Flashings Present @ Windows / Doors
Exterior Cladding Concrete-Composite Board (or Like) Hardie
ELEC Meter / Entry Location: Sideyard / Entry: Underground
Gas Main Location Exterior Side Yard / See Photo
Cooling Type / Year Not applicable / roughin?
Garage Motor Brand X2 See Photo / TESTED for operation
Garage HVAC Type Not applicable
the

insurance

Health & Safety
Limitations → Visibility / Access / fire sprinkler, not tested
Safety Features Present SD/CO Combo / replace at expiration.
Moisture, Gas & CO Meters used in suspect areas when applicable.
Moisture / Microbial No visible signs or too limited to confirm.
ALL Stairs-Railings Visibly inspected for common defficiencies
Garage Man-Door Self closing / Tested
Egress Windows Inspected for presence / Refer to code book
Interior & Laundry
Limitations → Visibility / Access / Obstructions
Thermostat Location Multiple Locations - Reset to default
Wall / Ceiling Matl. Drywall / (Flat) Scanned for common issues
Door / Windows A representative number tested under normal use.
Window Treatments Not applicable (consider accordion blinds)
Cabinetry / Built-in A representative number tested under normal use.
Baseboard / Casing Visually inspected for common defects
Flooring Materials Hardwood and Tile / UNPROTECTED / stains, debris
Fireplace Fuel Type(s) Natural Gas - restored to original settings
Washer & Dryer Tested for function & temperature variance
Kitchen & Bathroom
Limitations → Visibility / Access / Stored Items
Appliance /Condition Tested under normal use (NOT all settings) / GOOD
Fridge Waterline No access / further evaluation
Tap / Drain / P-Trap Rep. # tested under normal operation
Kitchen / Bath GFCIs Present / TESTED and restored to default
Tub/ Sink Over-flows “Splash” tested to mimic typical usage. MONITOR
Tub/ Shower Surround Inspected for common defects / Overflow tested
Bathroom Fan(s) Present / Tested for suction / SEE THERMAL
the

insurance

Mechanical
Limitations → Visibility / Access / Obstructions
Main Elect Panel Location: mechanical room
Main Amp Breaker 200 AMP / SEE Photo
Surge Protector Undetermined / Request disclosure
Wiring Material Copper / SEE PHOTO
AFCI Breakers Present / Not tested
Ground / Bonding Undetermined - Further Evaluate
Emergency Shut-Off Location: Switch present (before unit)
YEAR / Heating Type See Photo / x2 Gas Furn, Monitor for condensation.
Additional HVAC Heat recovery ventilation (HRV) x2
H₂O Supply / Main Public / Location: Mechanical Room
YEAR/ Hot Water Unit NG Tank / SEE DATA PLATE PHOTO
Visible waterline Matl: PEX (or like) EXT. shut-off present
Visible Sewer Matl. ABS / Recommend Sewer Scope Inspection
M•Drain/ Check Valve Present (Do Not Block!) / Underermined
Sump Pmp/ Sewer Lift Present (TESTED) / NA (Keep 2nd pump ON hand)
Manuals & Paper Work Please request from sellers or management
Structure & Therm
Limitations → 90% Covered / currently repairing settling stairs?
Thermal Scanned All visible appliances, walls, ceilings & floors.
Structure Type Engineered (TJI / LVL / Truss) & Dimensional
Roof Structure Truss / As seen from hatch
Interior Walls 2x4 Studs / 99% Not Visible
Exterior Walls 2x6 exterior studs / 99% Not Visible
Foundation Type Poured Concrete / Limited view / Visible Cracks
Slab Material Concrete / 95% Not Visible / Noted Cracks